Heart+ ResQ

Easy!

When a pad is attached, automatically analyze the ECG (electrocardiogram) and inform the necessity of electrical impulses by audio instruction system

Convenient!

Turn on the device and use a pad for adult/pediatric treatment connected in dvance

Smart!

Smart use from regular self-inspections and automatic audio recording of sounds from surrounding environment after attaching a pad

Safe!

Safe use from notifications for remaining battery, pad status, and operating temperature

 

Defibrillator

Defibrillator Series

Heart+ResQ ™ NT-381.C

Set Configuration

Defibrillator, battery pack, sealed electrode pads, Heart+ResQ User Guide, Protective Carrying Case,"NT-MPR" CD-ROM, Bluetooth Adaptor (optional)

Waveform

Truncated Exponential Biphasic

Energy

150J (adult, impedance 500)
50J (pediatric, impedance 50Q)

ShockChargelimeI

9 seconds (土10%)

Shock Method

Manual button (flashes when ready)

Mode Conversion

Adult/Child toggle button
(Child Mode delivers 50J Pediatric shock for patients weighing less than 25kg, approximately 12 months to 8 years old)

 

Physical

Dimensions

220mm (W) × 282mm (L) × 80mm (H)

Weight

2kg (including battery and pads)

 

Environmenta

Water resistance

IP55 per IEC 60529

Temperature

Operating: 0°C to 40°C
Storage: -20°C to 60°C

Humidity
(operating/storage)

10% to 95% Relative Humidity, Non-Condensing

Altitude
(operating/storage)

0 to 5000 meters

Drop test

1.5 meters per IEC 60068-2-32

 

ECG

ECG Record

LEAD II

Analysis Overview

Patient evaluated to determine whether ECG rhythm represents shockable or non-shockable state.
Shockable rhythms are ventricular fibrillation

Analysis time

Approx. 7 seconds (Read: about 5 seconds, Analyze: within 2 seconds)

 

Data

Storeda data

ECG recordings, operation information (whether shock delivered or not), ambient noise, self-diagnostics history

Memory capacity

ECG: consecutively make records during analysis and CPR (once in every 5 sec, up to 5,000 sec)
Audio recording: 60 min in total (4 recording files of 15 min)
Self-diagnosis: 3,000 cases and results

Storage type

Internal Memory

Access/search

"NT-ADV" Software (for PC) via Bluetooth

 

Self-diagnostics Test

Daily self-diagnostics tests ensure that circuits for measuring patient impedance, control circuit internal discharge of electric energy, and control circuit for charge/discharge of electric energy are functioning

Upon completion of daily self-diagnostics test, results are automatically stored within device's internal memory.

 

Battery Check

Battery Reserve Level

High: 3 bars
Medium: 2 bars
Low: one (1) bar ; red Status LED
Critical : no bars ;red Status LED

Battery Status Audible Warnings

Low: Voice prompt states
"Battery's voltage is low, check battery"
Critical: Voice prompt states
"Change cartridge"

 

Electrode pads

Shelf Life

2 years, for one-time use only

Conductive Gel

PE foam, Hydrogel

Conductive Element

AgCl (Silver Chloride)

Cable Length

2.1m (+1%)

Applicable Ages

All ages (12 months & older)

Sealing

Airtight

Size

125mm x 95mm

Pads Placement

Anterior-lateral (visual details on pads)

 

Battery pack

Type

Non-rechargeable lithium (LiMn02)

Voltage

DC 12V / 4,200mAH

Standby Mode Life

Recommended five (5) years @ 25°C

Capacity

180 shocks @ 25°C, 130 shocks @ 0°C

Dimensions

2.2cm (H) x 16.4cm (W) x 5.4cm (D)

Weight

260g (士10 %)